LEV LEV200: Hydraulic Aerial platforms automatic levelling system LEV201: Hydraulic Aerial platforms automatic levelling system with proportional outputs LEV285:Hydraulic Aerial platforms automatic levelling system with on/off outputs |
|---|---|
| Power Supply Voltage | 8V DC ÷ 32V DC |
| Absorbed current (without loads) | 18mA @ 12V |
| Solenoid Valves Current Range | from 0.3A to 1.7A |
| Maximum Current on Safety Outputs | 2A |
| Maximum Current on 'Oil Request' Output | 2A |
| Working Temperature | -15° C ÷ 70° C |
| Connectors | DIN 43650/ISO - 4400/6952 |
| IP Protection | IP55 |
| This device contains Mercury. Consult local regulations about correct disposing. | |
DESCRIPTION |
|
LEV reads continuously the slope of platform with an angle transducer and it proportionally regulates the oil flow into the two chambers of a levelling cylinder, keeping the platform in horizontal position during every conditions of work. Control unit has two safety by-pass outputs, these positives (2AMAX) outputs are electronic card independent, the first one is active when platform slope is between from -90° to +10°. |
|
CALIBRATION |
|
Before using the LEV, the installer must execute auto learning procedures, where control unit stores horizontal refernce position and electric/hydraulic properties of aerial platform. Befote to execute auto learning procedures, the installer must prepare aerial platform in a way that:
When platform is correctly opened yet, the installer must connect programming key into the internal connector and then he can switch on the control unit. Auto learning procedure will be ended only when L1 and L2 LED's will be both flashing. |
|
LEVELLING SWEETNESS CORRECTION |
|
![]() |
|
When levelling corrections are sudden, with many single correction action, the installer will have to regulate P1 or P3 trimming potentiometers in anticlockwise direction (adjust slowly). Otherwise if levelling corrections are too slow, the installer will have to regulate P1 or P3 trimming potentiometer in clockwise direction (adjust slowly). P1 trimming potentiometer regulates sweetness correction in one direction and P3 regulates sweetness correction in opposite direction. |
|
LEVELLING SPEED CORRECTION |
|
Sometimes, when LEV is mounted on big dimensions aerial platforms, the installer must regulate the speed of correction, to reduce the sensivity versus structure elastic oscillation. This regulations allows to reduce platform ascillation. Adjust P5 trimming potentiometer in anticlockwise direction to reduce the speed of correction , to adapt LEV to big structure. Regulate in clockwise direction to increase speed of correction, to adapt LEV to small or rigid structure. |
|
|
|
![]() |
|
OVERALL DIMENSIONS |
|
|
|