FSI/AN
Power Supply Voltage 10V DC ~ 32V DC
Max. Output Voltage Drop 5.5V
Ambient operating temperature -10 °C ~ +70 °C
Protection degree IP67
Resolution 0.11°
Current absorbed with output disconnected
18mA at 12V DC, 20mA at 24V DC
Answer time
164 ms
Precision @ Tamb 0° + 70° C
+/- 0.2°
Precision @ Tamb -10° + 70° C
+/- 0.6°

FITTING
When you have positioned the sensor, with the long side perfectly in horizontal position, it has an output current value between 11.9mA and 12.1mA. During the fitting, it is necessary to verify that the output current, in horizontal position, is between the upon mentioned values. Otherwise, you have to act on the support slots to place the sensor in a correct way.
WORKING

Supply the sensor and read the output current (directly with a milliamperometer or connecting it to a PLC with 4 ÷ 20mA current input.

Attention: the input resistance of the used instrument (for the measurement) must have a value that allows the sensor to supply the maximum current.

The maximum output tension of the sensor is "Vsupply -5.5V".